Specifications: Fluke 317/319 Clamp Meters
| General specifications | |
| Digital display | 6000 count resolution |
| Low battery Indication | Displays a signal when the batteries are below their required voltage |
| Power source | Three AAA IEC LR03 batteries |
| Clamp opening size | 1.45 in (37 mm) |
| Jaw diameter | 1.45 in (37 mm) |
| Dimensions (L x W x H) | 9.21 in x 2.95 in x 1.37 in |
| (234.0 mm x 75.0 mm x 34.8 mm) | |
| Weight | Approximately 13.5 oz (384 g) (batteries included) |
| Auto range | Available in Ohms |
| Safety | CE |
| EN/IEC 61010-1 and IEC 61010-2-032 | |
| Measurement Category: 600V CAT III | |
| 317 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω, 4000 Ω |
| Resolution | 0.1 Ω, 1 Ω | |
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | N/A |
| Frequency | Range | N/A |
| Accuracy | N/A | |
| Trigger Level | N/A | |
| 319 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600/1000 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω |
| 4000 Ω | ||
| Resolution | 0.1 Ω | |
| 1 Ω | ||
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | 100 ms |
| Frequency | Range | 5.0 – 500.0 Hz |
| Accuracy | 0.5% ±5 digit | |
| Trigger Level | 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A | |