Specifications: Fluke 317/319 Clamp Meters
General specifications | |
Digital display | 6000 count resolution |
Low battery Indication | Displays a signal when the batteries are below their required voltage |
Power source | Three AAA IEC LR03 batteries |
Clamp opening size | 1.45 in (37 mm) |
Jaw diameter | 1.45 in (37 mm) |
Dimensions (L x W x H) | 9.21 in x 2.95 in x 1.37 in |
(234.0 mm x 75.0 mm x 34.8 mm) | |
Weight | Approximately 13.5 oz (384 g) (batteries included) |
Auto range | Available in Ohms |
Safety | CE |
EN/IEC 61010-1 and IEC 61010-2-032 | |
Measurement Category: 600V CAT III |
317 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600 A} | ||
2.5% ±5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
319 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600/1000 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω |
4000 Ω | ||
Resolution | 0.1 Ω | |
1 Ω | ||
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | 100 ms |
Frequency | Range | 5.0 – 500.0 Hz |
Accuracy | 0.5% ±5 digit | |
Trigger Level | 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A |