Product overview: Fluke 107 Pocket Digital Multimeter
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry.
Fluke 107 measurement test functions
- AC and DC voltage
- AC and DC current
- Resistance
- Capacitance
- Diode
- Frequency and duty-cycle
-
SPECIFICATIONS :
-
Precision specifications AC voltage
(40 Hz to 500 Hz)1Range Resolution Accuracy 6.000 V
60.00 V
600.0 V0.001 V
0.01 V
0.1 V1.0 % + 3 DC voltage 6.000 V
60.00 V
600.0 V0.001 V
0.01 V
0.1 V0.5 % + 3 Exchange millivolts 600.0 mV 0.1 mV 3.0 % + 3 Diode test2 2.000 V 0.001 V 10 % Resistance
(ohm)400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3Capacitor3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5Frequency4 Hz
(10 Hz – 100 kHz)50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz0.1 % + 3 Duty cycle4 1 % to 99 % 0.10 % 1 % typical case5 AC current
(40 Hz – 200 Hz)4.000 A
10.00 A0.001 A
0.01 A1.5 % + 3 DC 4.000 A
10.00 A0.001 A
0.01 A1.5 % + 3 - All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
- Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
- The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
- All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
- Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
Features Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio AC voltage 600 V 1 >10 MΩ <100 pF 2 >60 dB at 50 Hz or 60 Hz at DC current − Exchange millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz − DC voltage 600 V 1 >10 MΩ <100 pF >100 dB at 50 Hz or 60 Hz at DC current >60 dB at 50 Hz or 60 Hz - Up to 6 x 105 V Hz
- For medium voltage (alternating current), the input impedance is approximately 1 MΩ.